Products Center

Environment. Health. Safety

Movable Arm Hood

Product model: BR-MO1D
Size: W400 x D400 x H960mm

Request a quote
  • Description
  • Specification
  • Background analysis


    Laboratory is a place for scientific research and experimental operation, which is widely used in the fields of education, research, production and quality inspection, but the health problems of people engaged in experimental work are worrying. The results of epidemiological studies in the United States, Sweden and the United Kingdom show that the mortality rate of chemical workers, especially laboratory workers, is much higher than that of the general population. Statistics released by the US Occupational Safety and Health Administration show that the life expectancy of laboratory workers is 10 years less than the average life expectancy of normal people.


    The air pollution in the laboratory is an important factor that endangers the physical and mental health of researchers. If the application of ventilation is not proper, it may aggravate the indoor air pollution and cause the external air pollution in the area.


    Based on the analysis of policies and regulations issued in recent years, relevant environmental regulations and documents will be gradually updated and improved in the future, and relevant requirements will be made from the latest laboratory volatile organic pollution prevention and control technical specification DB11/T1736-2020 released in 2020. Among them, laboratory units should establish the registration and management system for the use of organic solvents, and prepare experimental operation specifications. Select effective waste gas collection and purification devices to reduce VOCS volatile organic compound emissions and prevent pollution of the surrounding environment; The exhaust gas collection and purification device shall be ensured to be carried out simultaneously with the experimental operation.



    Product function


    Through the independent technology of GT SCIEN, BringHS toxic and harmful gas purification device further combines the physical, chemical and neutralization methods from the existing methods that rely on physical adsorption. It is the most suitable filtration system for removing harmful gases and odors of chemical substances. It can remove more than 99% harmful gases in the laboratory and extend the filter replacement cycle. Minimizes the possibility of re-threshing by reducing secondary contamination due to filter saturation and no longer removes harmful substances from additional reactions.


    Filter laboratory more than 99% of all harmful gases can be selected according to the reagent and operation characteristics of the filter, based on GT SCIEN harmful gas purification technology to achieve a tubeless structure, not only to protect the health and safety of users, but also to protect the external environment and energy saving, to establish a sustainable research and development environment. The application industry involves education and scientific research, inspection and quarantine, medical health, food and pharmaceutical, chemical and chemical industry, environmental safety, national defense and other fields.


    Product characteristic description


    1. Harmful gas filtration technology, through the independent technology of GT SCIEN, further combines the physical, chemical and neutralization methods from the existing way that relies on physical adsorption, and is the most suitable filtration system for removing harmful gases and odors of chemical substances.

    2. The seven-inch LED display, the use of touch panel, can automatically run through On/Off reservation and air quality perception, harmful gas monitoring and monitoring of VOC concentration in the laboratory and automatic start.

    3. The tubeless structure prevents harmful substances from flowing out of the source to prevent harmful substances from leaking and maintain constant temperature and humidity energy loss.

    4. Install melamine suction plate and vibration pad to minimize noise.

    5. Strong suction of fire-resistant chemical fan and engine, according to the degree of air pollution can control five wind speed.

    6. 360° full joint Flexible arm, positioning the suction inlet in the position of harmful gas generation




  • Product model: 

    BR460MA / BR800MT / BR-MO1D

    Size:W400 x D400 x H960mm
    Air capacity: 10 m³/min
    Power: 169W
    Noise: ≤60dB
    Voltage/frequency: 220V/50Hz
    Display: 7 "LED
    Wind speed control: 5 speed
    External arm: φ100mm, 850mm, 360 Angle rotatable flexible arm without joint
    Ambient temperature: -40°C to 80°C
    Bottom roller: a total of four, two universal wheel brake
    Weight: 65KG